Product Description
PTC-HPA50W is a Solid State High Power Amplifier, we customized all Amplifiers as per each client's request, this model with Ultra-wide bandwidth and high power output for option.
Product Parameters
ELECTRICAL SPECIFICATIONS
Parameter |
Specification |
Notes |
Operating Frequency Range |
1000-2000MHz |
|
Power Output @ P1dB |
50 Watt Typ |
CW |
Power Gain |
47 dB Min |
|
Power Gain Flatness |
4.0 dB p-p Max |
Constant input power |
Input / Output Return Loss |
10 dB Min |
Relative to 50 Ohm |
2-Tone Intermodulation (IMD) |
-30 dBc Typ |
40 dBm/Tone, Δ = 1 MHz |
Harmonics |
-20 dBc Typ |
-15dBc @ 1GHz - At rated Pout |
Spurious |
-50 dBc Max |
Non-harmonics |
Operating Voltage |
28 VDC Nom |
|
Current Consumption |
8 Amp Max |
At rated Pout |
Max Input Power Protection |
+8 dBm |
<10 Sec without damage |
Load VSWR Protection |
5 : 1 |
<1 minute at rated output |
Turn On / Off Speed |
5 µSec Max |
|
ENVIRONMENTAL CHARACTERISTICS
Parameter |
Specification |
Notes |
Operating Case Temperature |
-20 to +65 °C |
|
Storage Temperature |
-40 to +85 °C |
|
Relative Humidity |
5 to 95 % |
Non-condensing |
MECHANICAL SPECIFICATIONS
Parameter |
Specification |
Notes |
Dimensions |
300 x 600 x 27mm |
Excluding connectors |
Weight |
1.1 Kg. |
25kgs included rack |
RF Connectors In/Out |
SMA / Type-N female |
|
DC Power / Interface Connector |
Hybrid 9-Pin D-Sub |
9W4 |
Cooling |
External Heatsink |
Forced air required |
D-SUB CONNECTOR PIN ASSIGNMENT
Pin |
Function |
Description |
1 |
FWD |
OPTION 101 - Forward power detect |
2 |
VVA |
OPTION 103 - Variable Voltage Attenuator |
3 |
CURRENT SENSOR |
ID@20mV/100mA Typ |
4 |
TEMP SENSOR |
VT@10mV/°C + 500mV Typ |
5 |
SHUTDOWN |
TTL |
A1, A2 |
VDD |
28VDC |
A3, A4 |
GND |
Ground |
Product Advantages
Class A/AB linear GaN design
Rack mounted system
Instantaneous wide bandwidth
Suitable for broadband EMI/RFI, Lab, Comm., and EW applications
Suitable for pulse and all single channel modulation standards
Built-in protection circuits
High reliability and ruggedness for mobile applications
System control supports Ethernet Software remote control
Detailed Photos
Touchscreen
1. PA:current RF Output Power display;
2. ATT:Set and display the current attenuation value
(0-30dB range);
3. VSW:Display the current output standing wave
parameters of the module;
4. VSWR:Standing wave status;
5. Tmp:System temperature status;
6. OP:RF Output Power Status;
7. RF Output Control Switch:Press the switch to turn on the switch and the switch changed as blue color, changed to white color after pressed again to turn off the switch;
8. Temp:display the current system temperature;
ATT Value Input Interface
Click [ATT] to show the above interface then input the value of ATT from 0 to 30 then click [confirm].